Voltmeter Faceplate
Ambulance Type II Electrical Control System
KIT-01755-00000       Includes the following:

RCT-01755-00000     Plug-N-Play Power Center.

RCT-01894-00700     Dash 10 Switch Panel Staged Lighting.

RCT-01895-00700     Patient 12 Switch Panel Staged Lighting.

DAT-01350-00200     Dash Panel to Power Center.                   

DAT-01758-00150     Patient Panel to Power Center.  

DAT-01757-00200     A/C Heat Fan Switch to Thermostat.                           

DAT-01345-07200     Door Open Indicator to Power Center.

DAT-01347-01020     Power Center to ABC Body Flasher.

DAT-01348-01820     Dash Code Light to Patient Panel Code Switch.  

RCT-MOLEX-00011    Molex Connector Kit; complete for harness wires

Ambulance Type II Electrical Control System
KIT-01755-00001       Includes the following:

RCT-01755-00000     Plug-N-Play Power Center.

RCT-01940-00700     Dash 11 Switch Panel Staged Lighting.

RCT-01935-00700     Patient 14 Switch Panel Staged Lighting.

DAT-01350-00200     Dash Panel to Power Center.                   

DAT-01758-00150     Patient Panel to Power Center. 

DAT-01757-00200     A/C Heat Fan Switch to Thermostat.                           

DAT-01345-07200     Door Open Indicator to Power Center .

DAT-01347-01020     Power Center to ABC Body Flasher.

DAT-01348-00200     Dash Code Light to Patient Panel Code Switch.  

RCT-MOLEX-00011    Molex Connector Kit; complete for harness wires.

Carling Dimmer 12 VDC @ 10 Ampere
Documents:
Carling Dimmer LD3A1HH1-3AAFE-1FC.pdf

Carling Dimmer 12 VDC at 10 ampere.
MLB-50/200 Current Shunt.
Documents:
MLB-50-200 Current Shunt.

Use with RCT-00659, Amp Meter, +/- 200 ampere.
Light Control, Delay Off
Documents:
RCT-00130-00000 Light Delay.

 

Panel Mount, you may switch a load on and off. If load is left on it will delay out and switch off.

Motor Reversing, 12 VDC, Two Wire.
Documents:
RCT-00147-00000 Motor Reversing.

 

Motor Reversing Control, two wire, requires positive inputs for door operation. Door limits with negative inputs connected to this control. 

12 VDC up to 30 ampere.

Dual Latch Relay, 12 VDC, 30 Ampere.
Documents:
RCT-00162-00000 Dual Latch Relay.

 

Control will control two seperate loads with external "ON-OFF-ON' switch, two required. An unlimited number of switches may be used to control each of the two loads.

12 VDC up to 30 Ampere.

Power Center, Turtle Top
Documents:
RCT-00245-00000, Power Center, Turtle Top

Power Center, Turtle Top.

Use with Front Switch, PCB-00721-00000 only.

DAT-01350-00XX0 (15 Conductor Data Cabel) XX depicts length.

Exit Alarm, Five Zone, Indicating
Liquid Low Level Monitor
Documents:
RCT-00261-00000, Low Level Monitor.

 

Monitor's the level of any liguid. Will provde an output when a low level is reached.

High Side Switch
Documents:
RCT-00264-00000 High Side Switch.

 

Used to operate a 12 VDC up to 5 ampere. Is operated with a ground input. (15 ma sink)

Three Second Alarm
Documents:
RCT-00268-00000 Three Second Alarm.

 

Used to operate a three second alarm. Is operated with a ground input. (15 ma sink)

Pulsating Alarm
Documents:
RCT-00269-00000 Pulsating Alarm.

Continious Pulsating Alarm.

12 VDC at 5 Ampere.

Exit Alarm, Seven Zone, Indicating.
Documents:
RCT-00273 Brochure Seven Zone Exit Alarm.pdf

Exit, Door Window Alarm Indicator, Seven Zone.